170 resultados para Processamento digital : Imagem

em Repositório Institucional UNESP - Universidade Estadual Paulista "Julio de Mesquita Filho"


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Energia na Agricultura) - FCA

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Civil - FEIS

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate whether digitized images obtained from periapical radiographs taken with low dose of radiation could be improved with the aid of a computer software (PhotoStyler) for digital treatrnent. Serial and standardized radiographs of molar and premolar areas were studied. A total of 57 images equivalent to the radiographs taken with reduced exposure time ( 60 and 80% of the time considered normal), digitized and treated, were submitted to the evaluation of seven exanúners which compared them with those images without treatment. lt was verified that about 80% of the images equivalem to lhe radiographs taken with 60% reduction of ordinary exposure time were considered to having quality for supporting diagnosis. As for the images taken with 80% reduction of ordinary exposure time, about 50% of them were considered suitable for the sarne purpose

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVO: Avaliar o desempenho da análise de imagem digital na estimativa da área acometida pelas úlceras crônicas dos membros inferiores. MÉTODOS: Estudo prospectivo em que foram mensuradas úlceras empregando o método planimétrico clássico, utilizando desenho dos seus contornos em filme plástico transparente, medida sua área posteriormente por folha milimetrada. Esses valores foram utilizados como padrão para a comparação com a estimativa de área pelas fotografias digitais padronizadas das úlceras e dos desenhos das mesmas em filme plástico. Para criar um referencial de conversão dos pixels em milímetros, foi empregado um adesivo com tamanho conhecido, adjacente à úlcera. RESULTADOS: foram avaliadas 42 lesões em 20 pacientes portadores de úlceras crônicas de membros inferiores. As áreas das úlceras variaram de 0,24 a 101,65cm². Observou-se forte correlação entre as medidas planimétricas e as fotos das úlceras (R²=0,86 p<0,01), porém a correlação das medidas planimétricas com as fotos digitais dos desenhos das úlceras foi ainda maior (R²=0,99 p<0,01). CONCLUSÃO: A fotografia digital padronizada revelou-se método rápido, preciso e não-invasivo capaz de estimar a área afetada por úlceras. A avaliação das medidas fotográficas dos contornos das úlceras deve ser preferida em relação à análise de sua fotografia direta.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Comunicação - FAAC

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The comet assay is a method of DNA damage analysis widely used to quantify oxidative damage, crosslinks of DNA, apoptosis and genotoxicity of chemicals substances as chemical, pharmaceuticals, agrochemicals products, among others. This technique is suitable to detect DNA strand breaks, alkali-labile sites and incomplete excision repair sites and is based on the migration of DNA fragments by microeletroforesis, DNA migrates for the anode forming a “tail”, and the formed image has the appearance of a comet. The slides can be stained with fluorescence or silver, having differences in the microscopy type used for the analysis and the possibility of storage of the slides, moreover, the first one is a stained-method with more difficulties of accomplishment. The image analysis can be performed by a visual way, however, there is a disadvantage as the subjectivity on the results, that can be minimized by an automated method of digital analysis. This process was studied in this report with the aim to perceive the validation of the digital analysis turning it a quantitative method with larger reproductibility, minimizing the variability and imprecision due to the subjective analysis. For this validation we selected 50 comets photographed in a standardized way and printed, afterwards, pictures were submitted to three experienced appraisers, who quantified them manually. Later, the images were processed by free software ImageJ 1.38x, printed and quantified manually by the same appraisers. The intraclass correlation was higher to comet measures after image processing. Following, an algorithm of automated digital analysis from the measures of the comet was developed; the values obtained were compared with those 12 estimated manually after the processing resulting high correlation among the measures. The use of image analysis systems increases ...(Complete abstract click electronic access below)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Computed Radiography (CR) is a term used to describe the system that electronically records a radiographic image. CR systems use receivers or IP (imaging plate) to capture the analog signals and then allow the readers to do the image processing and converted into digital information. With the increasing expansion of the CR for medical diagnostics it is necessary that these systems receive the same type of monitoring related to Quality Control and Acceptance to the conventional processing systems. The current legislation fails to specify the parameters and procedures to be tested, allowing that somehow, some equipment is not fully able to use in clinical routine. In this project we used the standard AAPM Report Number 93, which is already fully established outside the country and displays all test parameters in CR. From there were chosen three types of tests that were performed in a satisfactory sampling of IP´s. With this procedure it was possible to establish which of those IP's should be out of use, which reveals the important purpose of the study, demonstrating the need for Quality Control Testing and Acceptance in Computerized Radiography as soon as possible are included in the legislation regulator in the country

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJETIVO: Avaliar a posição do supercílio em diferentes idades, utilizando medidas angulares. MÉTODOS: Foram avaliados indivíduos com idade de 4 a 6 anos (Grupo de crianças) e igual ou superior a 50 anos (Grupo de idosos), separados em faixas etárias, avaliando-se a posição do supercílio por meio de imagens digitais, utilizando medidas angulares. As imagens foram tomadas em posição primária do olhar, utilizando filmadora Sony Lithium, e posteriormente transferidas para computador MacIntosh G4 e processadas pelo programa NIH 1,58. Os parâmetros analisados foram: ângulo interno, externo e vertical da cauda do supercílio. As comparações foram entre sexos, faixas etárias e lateralidade. Os resultados obtidos foram submetidos à análise estatística. RESULTADOS: A comparação das medidas angulares mostrou que houve diferença significativa na posição da cauda do supercílio entre os grupos estudados quando comparados dentro do grupo com faixa etária semelhante. Porém, comparando-se crianças e adultos, houve diferença em todos os tipos de ângulos estudados. CONCLUSÕES: A posição do supercílio avaliada por medidas angulares mostrou diferenças entre crianças e idosos, revelando associação positiva com a idade.